Monthly usage ÷ 30. Check our panel calculator if you only know the monthly figure.

Lithium (LiFePO4)

0 kWh nominal
0 Ah at chosen voltage

Lead-acid

0 kWh nominal
0 Ah at chosen voltage

Lithium is sized assuming a 90% usable depth of discharge; lead-acid is sized assuming a 50% depth of discharge to protect battery lifespan.

How the battery calculator works Daily usage times the backup percentage gives target energy, then divided by battery usable depth to get real capacity. What you enter Daily usage kWh per day Backup wanted % of daily use Energy to store usage × backup % Divide by usable depth lithium ~90%, lead-acid ~50% Real battery capacity (kWh & Ah)
How the calculator turns your usage into real battery capacity.

Capacity vs how much backup you want

This curve updates with your inputs above. It shows the usable battery capacity (kWh) you need as you back up more of your daily usage — for both lithium and lead-acid.

Battery capacity needed rises with backup percentage; lead-acid needs far more capacity than lithium for the same backup.

Battery sizing trips up more people than any other part of a solar or backup system, mostly because of one detail that's easy to miss: the capacity printed on a battery isn't the capacity you can actually use. This calculator handles that automatically by comparing two of the most common battery chemistries side by side, so you can see how the choice of battery type changes the size — and cost — of what you need to buy.

Why nominal capacity isn't usable capacity

Every rechargeable battery has a depth of discharge (DoD) limit — the percentage of its total capacity that can be safely used before recharging, without significantly shortening its lifespan. Draining a battery further than its recommended DoD, especially repeatedly, degrades it much faster than the manufacturer's rated cycle life would suggest.

This is why the same daily backup target requires very different battery sizes depending on chemistry — the calculator above divides your target usable capacity by 0.9 for lithium and by 0.5 for lead-acid to arrive at the nominal (rated) capacity you'd need to purchase.

Field note

If the charge controller isn't programmed correctly for the battery type in use, it leads to fast, uncontrolled charge and discharge cycles instead of the gradual, protected cycling batteries are designed for — and that shortens their lifespan considerably. This is especially damaging for lead-acid batteries, which I've seen fail well before their rated cycle life simply because the controller settings were left on generic defaults instead of being matched to the actual battery bank.

Lithium vs. lead-acid: the full comparison

FactorLithium (LiFePO4)Lead-acid
Recommended DoD90–100%50%
Cycle life3,000–6,000 cycles300–800 cycles
Upfront costHigher per kWhLower per kWh
Cost per usable cycleOften lower long-termHigher long-term due to shorter life
WeightRoughly half of lead-acid for the same usable capacityHeavier, bulkier for the same usable capacity
MaintenanceMinimal to noneFlooded types need regular water top-ups; AGM is maintenance-free
Cold-weather performanceCharging below freezing needs a BMS with low-temp cutoffMore tolerant of cold, but capacity drops in low temperatures too

Lead-acid remains attractive for tight budgets or occasional backup use where the battery won't be cycled often. Lithium tends to win out for daily-cycling systems, off-grid homes, or anywhere weight and space are limited — the higher upfront cost is usually offset by a much longer service life.

Choosing how much backup you actually need

The backup percentage you pick has a bigger effect on cost than almost any other decision in the system. It helps to think in terms of what you're actually protecting against:

There's no universally "correct" answer here — it's a direct trade-off between upfront cost and peace of mind during outages.

A worked example

Say your daily usage is 20 kWh and you want 50% of that backed up on a 24V system. Your target usable capacity is 10 kWh. For lithium, that means a nominal capacity of about 11.1 kWh (10 ÷ 0.9), which works out to roughly 463 Ah at 24V. For lead-acid, the same 10 kWh target needs 20 kWh nominal (10 ÷ 0.5) — nearly double — which comes to about 833 Ah at 24V. This is exactly what the calculator returns with its default values, and it illustrates why lead-acid banks end up so much larger and heavier for the same real-world backup.

Related tools: check how long a given bank will last on a specific load with the battery runtime calculator, size the charge controller that will charge it, or plan a full system with the off-grid system wizard.

Frequently asked questions

Can I mix lithium and lead-acid batteries in the same bank?

This is generally not recommended. The two chemistries have different charging voltage profiles and charge/discharge characteristics, which can cause uneven charging, reduced lifespan, or damage to one or both battery types. Keep battery banks to a single chemistry.

Does battery capacity need to match my inverter size?

Not directly — they answer different questions. Inverter size is about how much power you can draw at once (see our inverter calculator), while battery capacity is about how much energy you can store and use over time. Both need to be sized for your system, but independently of each other.

Why does the calculator use kWh instead of just Ah?

Ah (amp-hours) only tells you the full story once you know the voltage, since energy (kWh) is voltage × amp-hours ÷ 1000. The calculator shows both: kWh as the voltage-independent figure for comparing battery types, and Ah at your chosen system voltage for matching against real battery specs.